ISO 5349-2 PDF

The ISO Central Secretariat accepts no liability in this area. International Standard ISO was prepared by the European Committee for. Buy KS B ISO Mechanical vibration — Measurement and evaluation of human exposure to hand-transmitted vibration — Part 2: Practical guidance. ISO MECHANICAL VIBRATION – MEASUREMENT AND EVALUATION OF HUMAN EXPOSURE TO HAND-TRANSMITTED VIBRATION – PART 2.

Author: Fenos Zolocage
Country: Vietnam
Language: English (Spanish)
Genre: Medical
Published (Last): 19 February 2004
Pages: 125
PDF File Size: 18.82 Mb
ePub File Size: 2.48 Mb
ISBN: 725-5-49966-489-1
Downloads: 93613
Price: Free* [*Free Regsitration Required]
Uploader: Shakanris

If the coating is not thought to be providing reduction in vibration exposure, either – remove the resilient material from the area beneath the transducers, or – fix the transducers using a force which fully compresses the resilient material.

This setting defines the actual measurement range of the instrument. The acceierometer or accelerometers is attached directly to the hole using a standard mounting stud.

This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3. The DC-shift distortion occurs in the transducer and is due to excitation of transients which are too large for the transducer, overloading the piezoelectric system mechanically.

Standard for instruments measuring human response to vibration. The examples are related to the measurement procedures specified in 5. The measurement locations defined in ISO are designed for a particular type of measurement usually single axis only and are not necessarily suitable for the evaluation of vibration exposure.

An Introduction to Hand/Arm Vibration – National Instruments

This part of ISO provides a means to determine the relevant operations which should be taken into account when determining the vibration exposure. The vibration exposure may vary greatly from one operation to another, either due to the use of different power tools or machines or different modes of operation of one power tool or machine.

Io directives help to establish a standard process by: The mounting system should be securely fitted to the vibrating surface, and all fixings should be carefully checked before and after measurement. Advantages Disadvantages Good frequency response Not affected by surface temperature Contact surface shall be flat Cannot be used on hand tools, where it might affect the electrical or 5394-2 safety of the power tool Figure D.

  ASKEP SECTIO CAESAREA PDF

They should not have any structural resonances which would affect the measured vibration.

The normal position of the transducer shall be halfway along the length of the handle. For difficult surfaces, individually moulded adaptors 5394-2 be suitable. However, it does not account for the vibration transmission properties of the resilient coating.

In other situations, changes have to be made to the power tools being used, e. For the use of mechanical filters to suppress vibration at very high frequencies, see annex C. For continuously operating rotary or rotary percussive tools, the Hanning window function is often suitable. It is important that FFT analyses use appropriate time windowing. The mounting of the transducers should be arranged so that the operator can work as normally as possible.

Therefore changes in apparent sensitivity should be noted and measurements discarded if necessary. In the interest isoo constant product improvement, specifications are subject to change without notice. Measurements shall be made on the main handle where the operator normally holds the power tool and applies the feed force. The second part of the day is spent using a chain saw, where trees are first felled and then the trunks are stripped of branches; 30 trees are felled and stripped per day.

An Introduction to Hand/Arm Vibration

For each casting the operator grinds around the circumference of the casting and then works on the upper and lower faces. The workers who are engaged in cleaning, grinding, and a few positions of assembly and use grinding machine, angle grinder, internal grinder, and percussion drill are exposed to vibrations with a high vibration acceleration and at a high position of the frequency spectrum.

The examples listed in Table A. Currently, there is no generally accepted way to convert the vibration emissions measurement reported by tool manufacturers 534-92 vibration exposure.

In this adopted standard, reference appears to ido International Standards for which Indian Standards also exist. Picking up, putting down or replacing the power tool or hand-held workpiece may disturb the measurement. Practical applications of the calculation of the daily vibration exposure are given In annex E.

  JOHN KANARY PDF

Where the user has to select the input range of the instrument, the appropriate measurement range can be determined by performing trial measurements. Faulty signal connections can show up simply as the loss of signal, in which case it appears that there Is sio vibration. The methods to be used will depend on the characteristics of the work environment, the work pattern and the vibration source. Total Daily Exposure Duration.

The distortion can show on a frequency analysis unrealistically high values of low-frequency vibration. Some of the ISO standards related to Hand-arm vibration are listed below: Metal or nylon straps have been successfully used.

Each cycle is made up o1 three periods of use; – 20 s to grind the circumference; – 40 s to grind the top face, the casting is then turned over, and – 40 s to grind the lower face.

InterRegs: EN ISO : | Mobile Construction Equipment

However, it is important to ensure that the information is compatible with the information required for an evaluation of daily vibration exposure. The daily vibration exposure, Aiiis given by equatfon 1 which for a single exposure is: Practical guidance for measurement in the workplace.

For each operation i, the vibration total value, afhvi. The uncertainties associated with the evaluation of.

МКС EN ISO 5349-2:2010/A1:2016

Work records show 534-92, on average, 50 vehicles are completed per day, i. It is very important to avoid interfering with the power tool controls or with the safe operation of a power tool or machine. In this case the transducer shall be placed as close as possible to the hand, between the thumb and the index finger, or as close as possible to the halfway location.

The position of the transducer shall be before the hand gripping area towards the driving direction to prevent impediments by gripping and ixo. In addition to vibration magnitude information, the evaluation of daily vibration exposure requires an evaluation of the exposure duration associated with each work phase.